FTP CAT 5E PVC
Product Name/Code: FTP Cat 5E PVC
Performance
Application: Frequency RL Attenuation NEXT PSNEXT
100 Base-T4 (MHz) (dB) (dB/100m)    
100 Base-TX min. max min (dB) min (dB)
100VG - AnyLAN 0.722 22.60 1.82 67.00 64.00
1000 Base-T (Gigabit Ethernet) 1.000 23.10 2.00 65.30 62.30
155 Mbps ATM 4.000 23.00 4.10 56.30 53.30
622 Mbps AT 8.000 24.50 5.80 51.80 48.80
Reference Standard 10.00 25.00 6.50 50.30 47.30
EIA/TIA 568B & ISO/IEC 11801 16.00 25.00 8.20 47.30 44.30
Cable Construction
20.00 25.00 9.30 45.80 42.80
Conductor Solid Bare Copper 25.00 24.20 10.23 44.30 41.30
AWG 24 31.25 23.30 11.71 42.90 39.90
Conductor Diameter(mm) 0.53 62.50 20.70 17.25 38.40 35.40
Insulation Solid PE 100.00 19.24 22.00 35.30 32.30
Average Thickness (mm) 0.2 Frequency ELFEXT PSELFEXT
ACR
Insulation Diameter(mm) 1.00 (MHz)    
Drain wire Tinned copper min (dB) min (dB)  
Construction (mm) 7/0.2 0.722 66.00 63.00   65.00
Al foil Aluminium/PET fiol 1.000 63.8 60.8   63.30
    4.000 51.7 48.7   52.20
    8.000 45.7 42.7   46.00
Sheathing PVC /FRPVC 10.00 43.8 40.8   43.80
Thickness(mm) 1.4 16.00 39.7 36.7 39.10
Diameter(mm) 5.8 20.00 37.7 34.7 36.50
    25.00 35.8 32.8 33.90
Core Identificatin/Color Code According to customer request 31.25 33.9 30.9 31.20
Bending Radius 6xOverall Diameter 62.50 27.8 24.8 21.40
    100.00 23.8 20.8 13.30
   
Fire Performance
Electrical Performance
Flame propagation Test to IEC 332 Part 1(PVC)
Flame Propagation Test to IEC 60332 Part 1 and Part 3(FRPVC)
Max.Conductor DC Resistance at 20 ℃(Ω/Km) <93.8
Operating Temperature( ℃ ) 70
Velocity of propagation 68%
Impedance(ohm) 100±15
Website: www.caledonian-cables.co.uk    